Capacity is a heat load, not a floor area
A rule of thumb will get you close in a well-insulated room with a normal ceiling. It fails in the houses this territory is full of: 1950s Bergvliet cottages with shallow lofts, Tokai homes extended over a garage, west-facing living rooms with single glazing, and roof voids with modest insulation.
The number that matters is the heat load under the condition you actually want to hold. Glazing area and orientation, ceiling height, roof insulation, occupancy and whether the room opens onto a hot passage all shift it. Two rooms of identical floor area can differ by a third in required capacity.
02
Oversizing is not a safety margin
An oversized unit cools the air quickly, reaches set point and shuts down before it has removed much moisture. The room feels clammy, the compressor cycles, and the machine wears faster. In humid Cape Town conditions that short cycling is the most common reason a well-known brand still feels poor.
The better answer is usually a smaller inverter unit run continuously, or a ducted system with properly balanced airflow, rather than a larger machine that slams on and off.
03
What to measure before choosing equipment
Measure the room, note window and door sizes and the direction they face, check whether the ceiling void is insulated, and identify where the outdoor unit can reject heat without recirculating it or annoying a neighbour. That last point often decides the layout before capacity does.
If the outdoor unit has to go on a boundary wall or under a window, ask about the noise rating at that distance rather than the headline figure on the brochure.